18.0 Fault Finding

© Baxi Heating UK Ltd 2008

Refer to Section 16.0 “Illustrated Wiring Diagram” for position of terminals and components
Central Heating - Follow operational sequence (do

Turn selector switch to

The display illuminates

Error 20, 28 or 50 flashing

Error 119 flashing

Burner lights

Error 110 flashing
Error 130 flashing
Error 133 flashing

Turn Central Heating

thermostat to Maximum.

Pump runs

Fan runs

Spark at ignition electrodes for

up to 5 seconds and for 3

attempts

3-way valve is open to Central

Heating circuit

Go to section ‘A’

Go to section ‘E’

Ensure all controls (and

integral clock if fitted) are

calling for heat

Go to section ‘K’

Go to section ‘B’

Error 160 flashing

Go to section ‘D’

Error 133 flashing

Burner does not stay alights

after 5 seconds

Error 133 flashing

Go to section ‘I’

Operation sequence

successful

If the error 110 is still flashing.

Go to section ‘J’

Fan runs at correct speed

YES

YES

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

YES

NO

YES

YES

YES

YES

NO

NO

NO

NO

NO

Burner output modulates to

maintain the temperature set

Burner goes out

Go to section ‘C’

Ensure controls are set to

demand and verify the

contacts are closed

Error 160 flashing

Go to section ‘L’

YES

Go to section ‘H’

Turn the selector switch to

reset

Go to section ‘F’

Error 130 flashing
Go to section ‘M’

YES

Check the Central Heating

NTC sensor

Go to section ‘E’

Fan stops after 10 seconds

Pump continues to run for 3

minutes

(room thermostat open)

NO

NO

YES

NO

YES

YES

Turn the selector switch to

reset position for 5 seconds

NO

Error 125 or 193 flashing

Ensure that primary

circulation is OK & that

there is no blockage

YES