14.0 Changing Components

© Baxi Heating UK Ltd 2008

14.11

Heat Exchanger Automatic Air Vent (Fig. 90)

1. Drain the boiler primary circuit and unscrew the

automatic air vent from the pump body.

2. Examine the ‘O’ ring seal, replacing if necessary, and fit it

to the new automatic air vent.

3. Reassemble in reverse order, transferring the grommet to

the new vent.

4. Ensure that the grommet is is sealed correctly to the

boiler top panel.

14.12

Pump - Head Only (Fig. 91)

1. Drain the boiler primary circuit and remove the socket

head screws securing the pump head to the body and draw

the head away.

2. Undo the screw on the pump wiring cover and remove

the cover. Using a suitable flat bladed screw driver press the

cable securing levers downwards to release each wire after

noting their position.

3. A standard replacement Grundfos 15-60 head can now

be fitted. Connect the pump wiring to the new head. The

pump speed must be set to 3 (Fig. 92).

4. Reassemble in reverse order.

14.13

Pump - Complete (Fig. 93)

1. Drain the boiler primary circuit.

2. Undo the two screws securing the body to the pipe and

manifold and draw the pump forwards.

3. Undo the screw on the pump wiring cover and remove

the cover. Using a suitable flat bladed screw driver press the

cable securing levers downwards to release each wire after

noting their position.

4. Unscrew the automatic air vent from the pump body.

5. Connect the wiring to the new pump. Examine the ‘O’

ring seals on the return pipe and manifold, replacing if

necessary.

6. Fit the air vent to the pump body and reassemble in

reverse order.

14.14

Automatic Air Vent (Fig. 93)

1. Drain the boiler primary circuit and unscrew the

automatic air vent from the pump body.

2. Examine the ‘O’ ring seal, replacing if necessary, and fit it

to the new automatic air vent.

3. Reassemble in reverse order.

Pump Setting

Socket Headed

Screw

Pump Head

Pump Body

Automatic Air

Vent

Fig. 91

Fig. 93

Fig. 92

Pump Wiring

Cover

Pump Wiring

Cover

Heat Exchanger

Air Vent

Grommet

Fig. 90