14.0 Changing Components

© Baxi Heating UK Ltd 2008

Central Heating

Temperature Sensor

Safety Thermostat

Flow Pipe

Fig. 88

DHW Temperature

Sensor

Fig. 89

Plate Heat

Exchanger

Pressure Sensor

Flue/Heat Exchanger

Thermostat Sensor

Electrical

Plug

Fig. 87

14.8

Flue/Heat Exchanger Thermostat Sensor
(Fig. 87)

1. Ease the retaining tab on the sensor away and disconnect

the electrical plug.

2. Turn the sensor 90

°

anticlockwise to remove - it is a

bayonet connection.

3. Reassemble in reverse order.

14.9

Water Pressure Sensor (Fig. 89)

1. Drain the primary circuit.

2. Disconnect the two wires from the sensor.

3. Undo the nut on the flow pipe securing and sealing the

sensor.

4. Remove the sensor, examine the sealing washer, replacing if

necessary.

5. Reassemble in reverse order. The component is not

polarised - either wire will fit each terminal.

14.10

Central Heating Temperature Sensor (NTC)
(Fig. 88)

1. Ease the retaining tab on the sensor away and disconnect

the electrical plug.

2. Unscrew the sensor from it’s pocket and reassemble in

reverse order. The plug will only fit one way.

14.11

Safety Thermostat (Fig. 88)

1. Pull the plug off the thermostat.

2. Remove the screws securing the thermostat to the

mounting plate on the flow pipe.

3. Reassemble in reverse order, ensuring that the plug is

pushed fully on.

14.12

DHW Temperature Sensor (NTC) (Fig. 89)

1. Turn off the mains cold water supply tap and draw off the

residual domestic hot water.

2. Ease the retaining tab on the sensor away and disconnect

the electrical plug.

3. Unscrew the sensor from the plate heat exchanger

manifold. Examine the sealing washer,replacing if necessary.

4. Reassemble in reverse order. The plug will only fit one way.