7.0 Site Requirement

© Baxi Heating UK Ltd 2008

7.3

Ventilation of Compartments

1. Where the appliance is installed in a cupboard or

compartment, no air vents are required.

2. BS 5440: Part 2 refers to room sealed appliances

installed in compartments. The appliance will run sufficiently

cool without ventilation.

7.4

Gas Supply

1. The gas installation should be in accordance with the

relevant standards. In GB this is BS 6891. In IE this is the

current edition of I.S. 813 “Domestic Gas Installations”.

2. The connection to the appliance is a 22mm copper tail

located at the rear of the gas service cock (Fig. 10).

3. Ensure that the pipework from the meter to the

appliance is of adequate size. Do not use pipes of a smaller

diameter than the boiler gas connection (22mm).

7.5

Electrical Supply

1. External wiring must be correctly earthed, polarised and

in accordance with relevant regulations/rules. In GB this is

the current I.E.E. Wiring Regulations. In IE reference should

be made to the current edition of ETCI rules.

2. The mains supply is 230V ~ 50Hz fused at 3A.

NOTE: The method of connection to the electricity

supply must facilitate complete electrical isolation of the

appliance.

Connection may be via a fused double-pole isolator

with a contact separation of at least 3mm in all poles

and servicing the boiler and system controls only.

7.6

Bath & Shower Rooms

1. As the boiler is fitted with an integral timer when

installed in a room containing a bath or shower it cannot

be fitted in zones 1 or 2. (Figs. 11 & 12 shows zone

dimensions for a bathtub. For other examples refer to

Section 601 of the Current I.E.E. Wiring Regulations).

Reference must be made to the relevant requirements.

In GB this is the current I.E.E. Wiring Regulations and

Building Regulations.

In IE reference should be made to the current edition of I.S.

813 “Domestic Gas Installations” and the current ETCI

rules.

Fig. 10

Gas Service Cock

Zone 2

Zone 1

Zone 0

Zone 2

Zone 3

Zone 3

Zone 2

Window
Recess

Window
Recess

0.6 m

2.4 m

Ceiling

Outside
Zones

Outside Zones

Zone 3

Zone 3

Zone 2

Zone 2

Zone 1

Zone 0

2.25 m

Zone 2

Window
Recess

3.0 m

2.4 m

0.6 m

Fig. 11

Fig. 12

In GB Only

In GB Only