Chapter 4 adjustments and settings for recording, 5 setting the time data, 0f:30:8 – Panasonic AJ-HDX400P User Manual

Page 32: 5-1 setting the user bits

Advertising
background image

Chapter 4 Adjustments and settings for recording

32

Tape continuity with the user bits

Selecting REGEN for the UB MODE item on the <TC/UB>
screen by performing menu operations will call up the user
bits recorded on the tape, making it possible to continue
recording from that value. However, it is not possible to record
the contents that were set.

<Note>
The time code/user bits are also recorded in the VIDEO AUX
area of the unit’s memory. The time code (VITC) is the same
value as the sub code area’s time code (LTC). The user bit
(VITC user bit) can be selected by menu operations using the
VITC UB MODE item on the <TC/UB> screen which is
accessed from the VTR MENU page, and it can be used for
different applications from the LTC.
Special information such as the camera’s frame rate is
recorded in the user bits (VITC’s user bits).

4-5 Setting the time data

The time code setting range extends from 00:00:00:00 to
23:59:59:29.

4-5-1 Setting the user bits

Memos and other information with up to 8 digits (dates, times)
in hexadecimal notation can be recorded on the sub code
track by setting the user bits.

1

Set the DISPLAY switch to UB.

2

Set the TCG switch to SET.

4

Set the TCG switch to F-RUN or R-RUN.

5

Open the <TC/UB> screen from the VTR MENU page
and select USER as the UB MODE item setting by
performing menu operations.

3

Set the user bits using the SHIFT button, UP (+) button
and DOWN (–) button.
SHIFT button:

This is used to cause the digit that is
to be set to flash. Each time it is
pressed, the flashing digit moves to
the right.

UP (+) button:

This increments the numerical value
of the flashing digit by 1.

DOWN (–) button: This decrements the numerical value

of the flashing digit by 1.

DISPLAY switch

Display window

TCG switch

DOWN (–) button

UP (+) button

HOLD switch

User bit memory function

The user bit settings (except for the actual time) are
automatically saved in the memory and retained even after
the power is turned off.

VITC’s user bits

¢¢

:0F:30:8¢

Checking information
for the 6 digits at right.

Tape management information

Renew frame flag

REC START/STOP mark

Camera shooting mode

600:

60i

308:

30P

208:

20P

158:

15P

108:

10P

068:

6P

Fixed value

Advertising