Chapter 7 Menu description tables

89

7-5-6 WHITE BALANCE MODE

AWB B

MEM
ATW
VAR

For selecting the allocation of the WHITE BAL
switch position and Bch.
MEM: The switch position and Bch are

allocated as memory values when
AWB is executed.

ATW: The position and Bch are allocated as

ATW start switch functions.

VAR: The color temperature of B can be set

to vary using the COLOR TEMP B
menu item.

COLOR TEMP B

3200K

:

5600K

For setting the color temperature when AWB
B has been set to VAR.

Item/

Data storage

Variable

range

Remarks

FILTER INH

ON
OFF

For selecting whether or not to keep the AWB
memory (Ach, Bch) data for each filter.
ON:

The data is kept in the two Ach and Bch
memories for each filter used.

OFF: The data is kept for each filter.

SHOCKLESS AWB

OFF
FAST
NORMAL
SLOW1
SLOW2
SLOW3

For selecting whether to set SHOCKLESS
AWB to ON (FAST/NORMAL/SLOW1-3) or
OFF.
The SHOCKLESS AWB function will work
only when MEM has been selected at the
AWB A item and AWB B item settings for the
A and B positions of the WHITE BAL switch,
and it ensures that no shocks will result when
the WHITE BAL switch is switched between
the PRST, A and B settings.
In addition, the switching time can be
selected.

AWB AREA

25%
50%
90%

For selecting the AWB detection area.
25%: An area near the screen center

equivalent to 25% of the screen is
detected.

50%: An area near the screen center

equivalent to 50% of the screen is
detected.

90%: An area equivalent to 90% of the

screen is detected.

AWB & ABB
OFFSET

ON
OFF

For selecting whether or not to reset the GAIN
and PED values on the ROP menu when
AWB or ABB is executed.
ON:

The values are not reset.

OFF: The values are reset.

COLOR TEMP PRE

3200K

:

5600K

For selecting the AWB PRE color
temperature.

AWB A

MEM
VAR

For selecting the allocation of the WHITE BAL
switch position and Ach.
MEM: The switch position and Ach are

allocated as memory values when
AWB is executed.

VAR: The color temperature of A can be set

to vary using the COLOR TEMP A
menu item.

COLOR TEMP A

3200K

:

5600K

For setting the color temperature when AWB
A has been set to VAR.

ATW SPEED

NORMAL
SLOW
FAST

For selecting the ATW control speed.

7-5-7 USER SW GAIN

Item/

Data storage

Variable

range

Remarks

S.GAIN

30 dB

2

O

For selecting whether or not to enable a
setting of 30 dB for SUPER GAIN.

2

: The 30 dB setting is enabled.

O

: The 30 dB setting is disabled.

36 dB

2

O

For selecting whether or not to enable a
setting of 36 dB for SUPER GAIN.

2

: The 36 dB setting is enabled.

O

: The 36 dB setting is disabled.

42 dB

2

O

For selecting whether or not to enable a
setting of 42 dB for SUPER GAIN.

2

: The 42 dB setting is enabled.

O

: The 42 dB setting is disabled.

48 dB

2

O

For selecting whether or not to enable a
setting of 48 dB for SUPER GAIN.

2

: The 48 dB setting is enabled.

O

: The 48 dB setting is disabled.

DS.GAIN

6 dB

: (30P)

2

O

For selecting whether or not to enable a
setting increase of 6 dB (30P) for DS.GAIN.

2

: The 6 dB setting increase is enabled.

O

: The 6 dB setting increase is disabled.

12 dB

: (15P)

2

O

For selecting whether or not to enable a
setting increase of 12 dB (15P) for DS.GAIN.

2

: The 12 dB setting increase is enabled.

O

: The 12 dB setting increase is disabled.

20 dB

: (6P)

2

O

For selecting whether or not to enable a
setting increase of 20 dB (6P) for DS.GAIN.

2

: The 20 dB setting increase is enabled.

O

: The 20 dB setting increase is disabled.

The underlining in the variable range column indicates the setting in the preset mode.

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

C U F E

DS.GAIN

10 dB

: (20P)

2

O

For selecting whether or not to enable a
setting increase of 10 dB (20P) for DS.GAIN.

2

: The 10 dB setting increase is enabled.

O

: The 10 dB setting increase is disabled.

C U F E

C U F E

15 dB

: (10P)

2

O

For selecting whether or not to enable a
setting increase of 15 dB (10P) for DS.GAIN.

2

: The 15 dB setting increase is enabled.

O

: The 15 dB setting increase is disabled.

C U F E

C U F E

Advertising