7-8-3 BATTERY SETTING1

AU-BP490

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

11.7

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.

AU-BP402

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.

HP-30A

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

11.8

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.

Item/

Data storage

Variable

range

Remarks

C U F

C U F

C U F

PRO14

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

13.4

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.

C U F

BP-H120

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

11.4

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.

C U F

TRIM14

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

13.6

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.

HYTRON50

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

13.5

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.

HYTRON100

2

/

AUTO
MANUAL

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:

The voltage is set automatically.

MANUAL: The voltage is set manually.

11.0

:

13.0

:

15.0

For selecting the voltage at which the battery
charge is to be considered nearly depleted in