Chapter 7 menu description tables, 7 maintenance, 6-3 lens file – Panasonic AJ-HDX400P User Manual

Page 91: 6-4 scene, 6-5 initialize, 7-1 system check, 7-2 diagnostic, 7-3 lens adj

Advertising
background image

7

Chapter 7 Menu description tables

91

7-6-3 LENS FILE

Item/

Data storage

Variable

range

Remarks

FILE NO.

1

:

8

For selecting the number of the lens file.

READ

For reading the data from the lens file.

WRITE

For writing the data in the lens file.

TITLE 1-8

************

For setting a title consisting of not more than
12 characters.

7-6-4 SCENE

Item/

Data storage

Variable

range

Remarks

READ USER DATA

For reading the data from the memory’s user
area.

SCENE SEL

1

:

4

For selecting the scene file.

WRITE

For writing the data in the scene file.

READ

For reading the data from the scene file.

RESET

For returning the SCENE FILE values to the
initial values.

TITLE 1-4

**********

For creating a title for a scene file.

7-6-5 INITIALIZE

Item/

Data storage

Variable

range

Remarks

READ FACTORY
DATA

For resetting all MENU (USER MENU, MAIN
MENU, OPTION MENU) values to factory
settings.

WRITE USER
DATA

For saving the user-specific menu data in the
camera memory.

7-7 MAINTENANCE

7-7-1 SYSTEM CHECK

Item/

Data storage

Variable

range

Remarks

COLOR CHECK

ON
OFF

For selecting ON or OFF for checking whether
or not the camera recorder is functioning
correctly.
The Y and RGB values at the center are
displayed in the viewfinder, and whether the
signals of each system are being processed
correctly from the optical system to the digital
system is indicated.

7-7-2 DIAGNOSTIC

FPGA (TG)

For displaying the version of the program
software used for the CCD drive.

Item/

Data storage

Variable

range

Remarks

CAMSOFT (IN)

For displaying the version of the software
used for the flash memory incorporated in the
microcomputer.

CAMSOFT (OUT)

For displaying the version of the software used
for the externally connected flash memory.

FONT ROM

For displaying the version of the font used for
the characters.

CAM TABLE

For displaying the version of the tables.

FPGA (CHARX)

For displaying the version of the program
software used for the characters.

FPGA (MEM)

For displaying the version of the program
software used for the memory.

7-7-3 LENS ADJ

Item/

Data storage

Variable

range

Remarks

F2.8 ADJ

ON
OFF

The iris is set to f/2.8 only when ON is set for
this item.

F16 ADJ

ON
OFF

The iris is set to f/16 only when ON is set for
this item.

The underlining in the variable range column indicates the setting in the preset mode.

Advertising