Oceanic Personal Dive Computer Veo 100Nx User Manual

Page 10

Advertising
background image

10

Oxygen Accumulation Bar Graph (O2BG)

The O2 Bar Graph (Fig. 2a) represents oxygen loading, show-

ing the maximum of either per dive accumulated oxygen, or 24

hour period accumulated oxygen.

As your oxygen exposure (accumulation) increases during the

dive, segments will add to the Bar Graph, and as loading

decreases, it will begin to recede, indicating that additional

exposure is allowed for that dive and 24 hour period.

Variable Ascent Rate Indicator (VARI)

The Variable Ascent Rate Indicator (Fig. 2b) provides a visual

representation of ascent speed (i.e., an ascent speedometer).

The segments of the Variable Ascent Rate Indicator represent

two sets of speeds which change at a reference Depth of 60 FT

(18 M). Refer to the chart for segment values.

WARNING: At depths greater than 60 FT (18 M),

ascent rates should not exceed 60 feet per minute

(18 meters per minute). At depths of 60 FT (18 M)

and shallower, ascent rates should not exceed 30

feet per minute (9 meters per minute).

Fig. 2 - O2BG and VARI

VARI

Deeper than 60 FT (18 M)

Segments

Ascent Rate =

Displayed

FPM

MPM

0

0-20

0 - 6

1

21-50 6.5-15

2

51-60 15.5-18

3

>60

>18

60 FT (18 M) & Shallower

Segments

Ascent Rate =

Displayed

FPM

MPM

0

0-10

0 - 3

1

11-25 3.5-7.5

2

26-30 8-9

3

>

30

>

9

a

b

Advertising