HIGH OXYGEN ACCUMULATION

The O2 Bar Graph displays either oxygen accumulated

during that nitrox dive, or during the repetitive nitrox dives

you conduct during that 24 hour period, whichever of the two

is greater at that time.

The O2 Bar Graph offers you a convenient way to consistently

monitor how close you are coming to the limits of oxygen

exposure. Use it as a visual reference to place a wider

margin of protection between you and the Limits.

If the theoretical amount of oxygen accumulated equals, or

exceeds, the limit for a single exposure, or the exposure limit

for a 24 hour period, Oxygen Dive Time Remaining becomes

zero (0:00) and the O2 Bar Graph will enter the O2 (Danger)

Zone (Fig. 49). The UP Arrow and the full O2 Bar Graph will

flash as a warning until the level of oxygen decreases below

the limit.

 Press/release the button momentarily (< 2 seconds) to

view the Alternate Displays.

 The unit will revert to the Main Display after 5 seconds.