12 troubleshooting guide 13 annexure – TechniSat S1 User Manual

Page 67

Advertising
background image

Function

Update for operating software and pre-pro-
gramming

LNC power supply:
LNC power

400 mA max.; double insula
ted

LNC voltage vertical

<14,0V no load, > 11,5 V at 400
mA

LNC voltage horizontal

< 20 V no load, > 17,2 V at 400
mA
LNC switched off in standby mode

22 kHz modulation:

22 kHz, Amplitude 0.6 V +/- 0.2 V

Programme memory/satellite positions:
No. of programmes Favourites list TV:

999 TV programmes

No. of programmes Favourites list Radio:

999 Radio programmes

Number of programmes:
Total list TV/Radio:

In total 6000 programmes can be
stored in the Total list

DiSEqC:
DiSEqC 1.0 and DiSEqC 1.2

SFI data:
SFI preview:

maximum 7 days in advance

Timer:
Events:

maximum 124 events, one year in advance

Remote control system:

RC-5

Subsystem address

8 (SAT 1), 10 (SAT 2)

Modulation frequency

36 kHz

Infrared wavelength

950 nm

Power supply:

Mains adapter:

Power requirement:
10 W

in standby mode

16 W

in operation, excl. LNC

23 W

recording mode, excl. LNC

32 W

recording mode / 400mA LNC cur-
rent

Nominal voltage:
230 V / 50 Hz alternating current

Input voltage:
180 V.... 250 V / 50 Hz alternating current

General:
Dimensions (WxDxH):

370 mm x 220 mm x 65 mm

Weight:

approx. 2,7 kg