4 panel operation procedure – Tandberg Data Autoloader Tandberg LTO2 User Manual

Page 38

Advertising
background image

- 22 -

Important

The LTO2 Autoloader w/BCR requires a free slot used to swap cartridge
during the inventory scan process. Thus the maximum cartridge capacity of
the LTO2 Autoloader w/BCR is changed from 10 to 9. But if you prefer
to use 10 cartridges, the BCR function will need to be changed disabled.
In this case, please contact your nearest Customer Support Center.



3.5.4 Panel Operation Procedure


1. Press the right side ( | ) of the Autoloader power switch to switch the power ON.

2. When the power is supplied, the POWER LED lights in green and the power-on test starts.

3. When the power-on test ends, "READY" is displayed on the LCD.

4. Press the ENTER key and enter the main menu.

5. Press the arrow key and select the command. (The menu scrolls.)

6. Press the ENTER key and define the selected command.

7. Refer to “3.5.5 Menu Tree” and follow the system of operation commands to repeat
aforementioned
Steps 5 and 6, select the command to be executed, and define it.

8. To cancel the defined command during this procedure, press the ESCAPE key.
(A press of the ESCAPE key results in a return to the previous menu.)

9. Press the ENTER key and execute the menu.