Model number description – Trane RT-PRC005 User Manual

Page 10

Advertising
background image

10

RT-PRC005-EN

Model
Number
Description

DIGIT 1 - Unit Function

T = DX Cooling

DIGIT 2 - Efficiency

S = Standard Efficiency
H = High Efficiency

DIGIT 3 - Airflow

C = Convertible

DIGITS 4,5,6 - Nominal Gross Cooling
Capacity (MBh)

036 =

3 Ton

048 =

4 Ton

060 =

5 Ton

072 =

6 Ton

090 =

7½ Ton, Single Compressor

092 =

7½ Ton, Dual Compressor

102 =

8½ Ton

120 =

10 Ton

DIGIT 7 - Major Design Sequence

A = First

DIGIT 8 - Unit Voltage

1 = 208-230/60/1
3 = 208-230/60/3
4 = 460/60/3
W = 575/60/3
K = 380/60/3

DIGIT 9 - Unit Controls

E = Electromechanical
R = ReliaTel™Microprocessor

DIGIT 10 - Heating Capacity

0 = No Electric Heat
A = 5 kW (1 phase)
B = 6 kW (3 phase)
C = 9 kW (3 phase)
D = 10 kW (1 phase)
E = 12 kW (3 phase)
F = 14 kW (1 phase)
G = 18 kW (1 and 3 phase)
J = 23 kW (3 phase)
K = 27 kW (3 phase)
N = 36 kW (3 phase)
P = 54 kW (3 phase)

DIGIT 17 - Condenser Coil Protection

0 = Standard Coil
1 = Standard Coil with Hail Guard
2 = Epoxy Coated Condenser Coil
3 = Epoxy Coated Condenser Coil with

Hail Guard

DIGIT 18 - Through the Base Provisions

0 = No Through the Base Provisions
A = Through the Base Electric

DIGIT 19 - Disconnect/Circuit Breaker

(3 phase only)

0 = No Disconnect or Circuit Breaker
1 = Non-Fused Disconnect
2 = Circuit Breaker

DIGIT 20 - Convenience Outlet

0 = No Convenience Outlet
A = Unpowered Convenience Outlet
B = Powered Convenience Outlet

(3 phase only)

DIGIT 21 - Communications Options

0 = No Communications Interface
1 = Trane Communications Interface
2 = LonTalk® Communications Interface
3 = Novar 2024 Controls
4 = Novar 3051 Controls

DIGIT 22 - Refrigeration System Option

0 = Standard Refrigeration System
A = Thermal Expansion Valve (TXV)
B = Dehumidification (Hot Gas Reheat Coil)

DIGIT 23 - Refrigeration Controls

0 = No Refrigeration Control
1 = High Pressure Control
2 = Frostat
3 = Crankcase Heater
4 = High Pressure Control and Frostat
5 = High Pressure Control and Crankcase

Heater

6 = Frostat and Crankcase Heater
7 = High Pressure Control, Frostat and

Crankcase Heater

DIGIT 24 - Smoke Detector

0 = No Smoke Detector
A = Return Air Smoke Detector
B = Supply Air Smoke Detector
C = Supply and Return Air Smoke

Detectors

DIGIT 25 - Monitoring Controls

0 = No Monitoring Control
1 = Clogged Filter Switch
2 = Fan Failure Switch
3 = Discharge Air Sensing Tube
4 = Clogged Filter Switch and Fan Fail

Switch

5 = Clogged Filter Switch and Discharge

Air Sensing Tube

6 = Fan Fail Switch and Discharge Air

Sensing Tube

7 = Clogged Filter and Fan Fail Switches

and Discharge Air Sensing Tube

8 = Novar Return Air Sensor

T

S

C 036 A

3

R

B

A

**

C

0

0

0

A

1

0

0

0

1

A

1

1

2

3 4,5,6 7

8 9

10 11 12,13 14 15 16 17

18 19 20 21

22 23 24 25

DIGIT 11 - Minor Design Sequence

A = First Sequence

DIGITS 12, 13 - Service Sequence

**= Factory Assigned

DIGIT 14 - Fresh Air Selection

0 = No Fresh Air
A = Manual Outside Air Damper 0-50%
B = Motorized Outside Air Damper 0-50%
C = Economizer, Dry Bulb 0-100%

without Barometric Relief

D = Economizer, Dry Bulb 0-100%

with Barometric Relief

E = Economizer, Reference Enthalpy

0-100% without Barometric Relief

F = Economizer, Reference Enthalpy

0-100% with Barometric Relief

G = Economizer, Comparative Enthalpy

0-100% without Barometric Relief

H = Economizer, Comparative Enthalpy

0-100% with Barometric Relief

DIGIT 15 - Supply Fan/Drive Type/Motor

0 = Standard Drive
1 = Oversized Motor
2 = Optional Belt Drive Motor

DIGIT 16 - Hinged Service Access/Filters

0 = Standard Panels/Standard Filters
A = Hinged Access Panels/Standard Filters
B = Standard Panels/2” Pleated Filters
C = Hinged Access Panels/2” Pleated Filters

Example:

Example:

Example:

Example:

Example:
Model number TSC036A3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/60/3 power
supply, ReliaTel™ controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard direct drive motor, standard access panels/
filters, standard condenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard
refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.