General data (6 - 10 ton), Standard efficiency – Trane RT-PRC005 User Manual

Page 12

Advertising
background image

12

RT-PRC005-EN

General
Data

(6 - 10 Ton)

Standard Efficiency

Table GD - 2— General Data

6 Ton

7½ Ton

8½ Ton

10 Ton

Convertible Units

Convertible Units

Convertible Units

Convertible Units

TSC072A3, A4, AW, AK

TSC090A3,A4,AW, AK

TSC092A3, A4, AW

TSC102A3, A4, AW, AK

TSC120A3, A4, AW, AK

Cooling Performance

1

Gross Cooling Capacity

72,000

95,000

92,000

105,000

118,000

EER

2

10.3

10.3

10.3

10.3

10.4

6

Nominal CFM / ARI Rated CFM

2,400/2,100

3,000/2,625

3,000/2,625

3,400/3,000

4,000/3,200

ARI Net Cooling Capacity

69,000

90,000

87,000

100,000

7

112,000

7

Integrated Part Load Value (IPLV)

3

11.1

8

11.9

8

11.5

8

System Power (kW)

6.7

8.74

8.45

9.71

9

10.77

9

Compressor

No./Type

1/Scroll

1/Scroll

2/Scrolls

2/Scrolls

2/Scrolls

Outdoor Sound Rating (dB)

4

88

90

87

86

86

Outdoor Coil — Type

Lanced

Lanced

Lanced

Lanced

Lanced

Tube Size (in.) O.D.

0.3125

0.3125

0.3125

0.3125

0.3125

Face Area (sq ft)

13.88

17.00

17.00

19.83

25.92

Rows/FPI

2/17

3/17

2/17

2/17

2/17

Indoor Coil — Type

Lanced

Lanced

Lanced

Lanced

Lanced

Tube Size (in.)

0.3125

0.3125

0.3125

0.3125

0.3125

Face Area (sq ft)

9.89

9.89

9.89

12.36

12.36

Rows/FPI

2/16

3/16

3/16

3/16

4/16

Refrigerant Control

Short Orifice

Short Orifice

Short Orifice

Short Orifice

Short Orifice

Drain Connection No./Size (in.)

1/¾ NPT

1/¾ NPT

1/¾ NPT

1/¾ NPT

1/¾ NPT

Outdoor Fan — Type

Propeller

Propeller

Propeller

Propeller

Propeller

No. Used/Diameter (in.)

1/26

1/26

1/26

1/26

1/26

Drive Type/No. Speeds

Direct/1

Direct/1

Direct/1

Direct/1

Direct/1

CFM

6100

6200

6500

7100

7000

No. Motors/HP

1/0.70

11

1/0.70

11

1/0.70

1/0.75

1/0.75

Motor RPM

1115

1115

1115

1115

1115

Belt Drive Indoor Fan — Type

FC Centrifugal

FC Centrifugal

FC Centrifugal

FC Centrifugal

FC Centrifugal

No. Used

1

1

1

1

1

Diameter x Width (in.)

12 x 12

12 x 12

12 x 12

15 x 15

15 x 15

Drive Type/No. Speeds

Belt/Variable Speed

Belt/Variable Speed

Belt/Variable Speed

Belt/Variable Speed

Belt/Variable Speed

No. Motors

1

1

1

1

1

Motor HP (Standard/Oversized)

1.00/2.00

12

2.00/3.00

2.00/3.00

2.00/3.00

3.00/5.00

Motor RPM (Standard/Oversized)

1750

1750

1750

1750

1750/3450

Motor Frame Size

56

56

56

56

56

Filters — Type Furnished

10

Throwaway

Throwaway

Throwaway

Throwaway

Throwaway

(No.) Size Recommended (in.)

(4) 16 x 25 x 2

(4) 16 x 25 x 2

(4) 16 x 25 x 2

(4) 20 x 25 x 2

(4) 20 x 25 x 2

Refrigerant Charge (Lbs of R-22)

5

7.1

11.9

6.2 Circuit 1

7.9 Circuit 1

8.4Circuit 1

3.4 Circuit 2

4.0 Circuit 2

6.6 Circuit 2

NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net

and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz).

2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb ar ARI

rated cfm.

4. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-51.
5. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
6. EER shown is for downflow airflow. EER for horizontal airflow is 10.3.
7. ARI Net Cooling Capacity shown is for downflow airflow. Cooling Capacity for Horizontal airflow TSC102A is 99,000; TSC120A is 111,000.
8. Integrated Part Load Value (IPLV) shown is for downflow airflow. IPLV for Horizontal airflow TSC092A is 10.8, TSC102A is 11.5; TSC120A is 11.0.
9. System Power (kW) shown is for downflow airflow. System Power (kW) forHorizontal airflow TSC102A is 9.61; for TSC120A is 10.78.
10. Optional 2” Pleated Filters also available.
11. Outdoor motor is 0.75 hp for AK (380V/60 Hz units).
12. Standard indoor motor is 2.00 hp for AK (380V/60 Hz) units.