Ultimate Technology 600 POS User Manual

Page 20

Advertising
background image

Series 600 POS Keyboard

15

Table 2. Local Mode Programming Instructions

* = Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

02

Code Primary Key
Functions to
Secondary Key
Positions

1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard

numeric keypad, enter Function Code 02.

LED (2) turns on.

2. At the Series 600 Keyboard, press the designated key to copy its primary function

into the secondary position.

3. Repeat 2 for next key to be programmed.

4. When completed, press ENTER.

LED (2) turns off.

5. Program the next function code or exit programming mode by entering 99 on Series

600 Keyboard numeric keypad or by swiping the Program Card.

Note: A Sec Op Key or Sec Op Lock Key must be programmed in the primary function
mode in order to use secondary function codes.

03

04

Program Primary
OPOS Keys (03)
and Secondary
OPOS Keys (04)

The keys on the Series 600 Keyboard can be programmed to output unique key codes.
These keys are used with the UTC OPOS keyboard driver. These key codes cannot be
reproduced on a standard keyboard.

1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard

numeric keypad, enter Function Code 03 for primary key or 04 for secondary key
function.

LED (2) turns on.

2. At the Series 600 Keyboard, press the key to be programmed.

LED (2) flashes.

3. On the Series 600 keypad, type the number of the desired OPOS key to be used 01-

50 and then hit the keypad ENTER on the Series 600 Keyboard.

If LED (2) stops flashing, repeat
step 2.

4. Repeat 2 and 3 for next key to be programmed.

5. Exit programming primary/secondary OPOS key functions by pressing 99 on the

Series 600 Keyboard numeric pad.

Advertising