Series 600 POS Keyboard

23

Table 2. Local Mode Programming Instructions

* = Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

38
39
40
41
42
43

Keyswitch
Position 1
MAKE (38)

Keyswitch
Position 1
BREAK (39)

Keyswitch
Position 2
MAKE (40)

Keyswitch
Position 2
BREAK (41)

Keyswitch
Position 3
MAKE (42)

Keyswitch
Position 3
BREAK (43)

1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard

numeric keypad, enter applicable Function Code 38, 39, 40, 21, 42, or 43.

LED (2) flashes.

2. At the auxiliary keyboard, type the desired MAKE or BREAK key sequence shown

below and/or desired key sequence. Note that the maximum number of key codes is
limited to 24 – this is equivalent to approximately 12 key strokes.

If the Series 600 Keyboard beeps and
LED (2) turns off while entering key
codes at the auxiliary keyboard, you
have exceeded 24 key codes. Repeat
steps 1 and 2.

3. At the Series 600 Keyboard, press ENTER.

LED (2) turns off.

4. Program the next function code or exit programming mode by entering 99 on Series

600 Keyboard numeric keypad or by swiping the Program Card.

44

Poll
Keyswitch

1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard

numeric keypad, enter Function Code 44.

LED (2) turns on.

2. At Series 600 Keyboard numeric keypad, enter the applicable number (0 or 1) to

select polling method per list below.


0 = Send on change or transition
1 = Send only with poll command B7

LED (2) turns off.

3. Program the next function code or exit programming mode by entering 99 on Series

600 Keyboard numeric keypad or by swiping the Program Card.