Series 600 POS Keyboard

45

Table 5. Remote Programming Mode Commands

OP CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

A7

NVBDRD


Read a database register.

COMMAND:

A7hhhm<CR>


A7

= Op Code

hhh

= 3 character address representing

the register to read range "000" to "7FF"
in ASCII

m

= mode to read in

0 = string mode up to null

1 = raw mode

read as CxDx (16 bytes)

<CR>

= terminate command (0D hex)


ACKNOWLEDGEMENT: NONE

A8

NVBDWR


Write a database register.

COMMAND:

A8hhhxx..x<CR>


A8

= Op Code

hhh

= 3 character address representing

the register to write

xx

= data to write in ASCII or CxDx

pairs (16 bytes max.)

<CR>

= terminate command (0D hex)


ACKNOWLEDGEMENT: NONE

A9

NVBDCLR


Clear all database registers.

COMMAND:

A9CLR<CR>


A9

= Op code

CLR

= required for failsafe operation

<CR>

= terminate command (0D hex)


ACKNOWLEDGEMENT: NONE

AA

CDSECOPN

Used to disable keyboard output if cash
drawer(s) are open.

COMMAND: AAx<CR>


AA

= Op code

x

A = normal
B = cash drawer 1
C = cash drawer 2
D = both drawers

ACKNOWLEDGEMENT: NONE