48

Table 5. Remote Programming Mode Commands

OP CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

B1

BEEPON


Controls pitch and duration of beep. If
valued for pitch (p) and duration (d) omitted
when command activated.

COMMAND:

B1pd<CR>


B1

= Op Code

p

= pitch in Hz

d

= duration in milliseconds

<CR>

= terminate command (0D hex)


pitch (Hz) in ASCII

0 = 500

5 = 880

1 = 2000

6 = 1320

2 = 220

7 = 1760

3 = 440

8 = 2640

4 = 660

9 = 3520

duration (mS) in ASCII

0 = 1000

5 = 500

1 = 100

6 = 600

2 = 200

7 = 700

3 = 300

8 = 800

4 = 400

9 = 900


ACKNOWLEDGEMENT: NONE

B2

SENDP


Sends data to selected port: main serial
port, auxiliary serial port, or auxiliary
keyboard port.

COMMAND:

B2p...........<CR>


B2

= Op Code

p

= data destination port

<CR>

= terminate command (0D hex)


p:

0 = serial port 0 (main)

1 = serial port 1 (auxiliary)

2 = keyboard port 0 (main)

3 = keyboard port 1 (auxiliary)

4 = cash drawer 1 fire

5 = cash drawer 2 fire


Where data can be ASCII or CxDx (high and low
nibble hex value) type.

ACKNOWLEDGEMENT: NONE