Series 600 POS Keyboard

62

2. At the source keyboard, swipe the Program Card in the magnetic stripe reader (MSR). For

keyboards equipped with an optional keyswitch adjacent to the LED indicators, set the
switch to the AUX position, then enter 882 at the numeric keypad.

3. All LED indicators turn on and the keyboard enunciator beeps three times.

4. At the source keyboard numeric keypad, enter 98.

5. Exit the local programming mode by typing 99 on the source keyboard numeric keypad or

by swiping the Program card. For keyboards equipped with an optional keyswitch, move the
switch out of the AUX position. This returns the keyboard to normal operation.

6. Repeat steps 1 through 5 for next target keyboard or disconnect equipment.

OPERATOR'S AND PROGRAMMER'S MAGNETIC CARDS

Secure and Program magnetic cards are available for purchase from Ultimate Technology
Corporation should the need for replacement or customized cards be required.

SYSTEM LOG

The Series 600 POS Keyboard maintains a system log to monitor and record both external and
internal operating events. When Function Code 90 is entered at the keyboard, this system log
data is transferred via the keyboard main port to a terminal/PC for monitoring or for capture as a
data file. Refer to Table 3 for instructions needed to initiate Function Code 90.