Table 5. Remote Programming Mode Commands

OP CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

BE

VERSION


Sends software version, engineering
number, and keyboard type parameters.

COMMAND:

BE<CR>


BE

= Op Code

<CR>

= terminate command (0D hex)


ACKNOWLEDGEMENT:

BEnnnnnvvvvkkkkx-x<CR>

BE

= Op Code

nnnnn

= engineering number

vvvv

= software version

kkkk

= keyboard type installed

x-x

= notes (maximum of 40 characters)

BF

GETSET


Sends each key macro, all keyboard
communication parameters. Keeps
sending until all data has been transferred.
Structure of data is in load command
format (MACROK).

COMMAND:

BF<CR>


BF

= Op Code

<CR>

= terminate command (0D hex)


ACKNOWLEDGEMENT:
BF...............<CR>


101/102-KEY KEYBOARD - KEY CODE IDENTIFICATION


As shown in Appendix D, a specific Key Code number is assigned for each of the keys on the
standard 101/102 key keyboard. These key code numbers are decimal numbers not ASCII
values. Use of key code numbers provides a more positive way for identifying a specific key than
using its name. Different keyboard types may have different names assigned to the same key, but
the key code is the same for that position. For example, on the 101/102-key keyboard shown in
Appendix D, key code 31 identifies the "A" key. Assignment of different key codes to keys that
produce the same scan codes or have similar functions is done so that like keys can be used for
other functions. For example, the left and right ALTERNATE keys are assigned key codes 60 and
62, respectively.