Ultimate Technology 600 POS User Manual

Page 21

Advertising
background image

Series 600 POS Keyboard

16

Table 2. Local Mode Programming Instructions

* = Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

08

Enable/Disable
Magnetic Stripe
Reader (MSR)
Tracks

1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard

numeric keypad, enter Function Code 08.

LED (2) turns on.

2. At the Series 600 Keyboard numeric keypad, enter the applicable number (1 through

7) to select the MSR track configuration per list below.

1 = Track 1 enabled only
2 = Track 2 enabled only
3 = Track 3 enabled only
4 = Tracks 1 and 2 enabled *
5 = Tracks 2 and 3 enabled
6 = All tracks disabled
7 = OPOS mode tracks 1 and 2

LED (2) turns off.

3. Program the next function code or exit the local programming mode by entering 99 on

Series 600 Keyboard numeric keypad or by swiping the Program Card.

Note: Disabling all format tracks will not disable the SECURE or PROGRM cards.

09

Magnetic Stripe
Reader (MSR)
Beeper

1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard

numeric keypad, enter Function Code 09.

LED (2) turns on.

2. At the Series 600 Keyboard numeric keypad, enter the applicable number (1 through

4) to select the magnetic stripe reader beeper operation per list below.

1 = beep on good read for all enabled tracks
2 = beep on bad read for all enabled tracks
3 = beep on good or bad read of enabled tracks*
4 = no beep on good or bad reads

LED (2) turns off.

3. Program the next function code or exit the local programming mode by entering 99 on

Series 600 Keyboard numeric keypad followed by ENTER or by swiping the Program
Card.

Advertising