Xilinx V2.1 User Manual

Page 82

Advertising
background image

82

Xilinx Development System

Xilinx System Generator v2.1 Reference Guide

Block Parameters Dialog Box

The block parameters dialog box can be invoked by double-clicking the icon in your
Simulink model.

Figure 3-54: Accumulator block parameters dialog box

Parameters specific to the block are:

Number of Bits (output width)

: specifies the output width which must

match the input width. If the data input does not match the output width, an error
is reported.

Overflow

: specifies behavior on internal overflow to be Wrap, Saturate, or flag as

an Error.

Operation

: This is a list of two choices: add and subtract. This determines

whether the block is adder or subtractor based.

Feedback Scaling

: specifies the feedback scale factor to be one of the

following:
1, 1/2, 1/4, 1/8, 1/16, 1/32, 1/64, 1/128, or 1/256.

Reset to input

: when selected, the output of the accumulator is loaded by the

data on input port b whenever the accumulator is reset. When not selected, the
output of the accumulator is reset to 0.

The type of the output is the same as that of the input. The block always has a latency
of 1.

Other parameters used by this block are explained in the Common Parameters section
of the previous chapter.

Xilinx LogiCORE

The block always uses the Xilinx LogiCORE Accumulator V5.0. The data width must
be between 1 and 258, inclusive.

The Core datasheet can be found on your local disk at: