Table 3-1, Charging current guidelines –5 – Xantrex Technology ENERGY HW 1000 User Manual

Page 35

Advertising
background image

Adjusting Feature Settings

975-0467-01-01

3–5

To change the inverter mode setting:

By default the
inverter mode is
set to ON.

ON (“In1”) will put the inverter on standby. This means when
shorepower is present, AC shorepower will pass through as AC output.
And when shorepower is not available, the inverter function will take
power from the battery and provide AC output power. When the inverter
mode is ON, you can manually turn the inverter function ON or OFF by
using the Power button. See

“Operating in Inverter Mode” on page 4–4

.

OFF (“In0”) will completely disable inverter function. This means when
shorepower is present, AC shorepower will still pass through as AC
output. However, when shorepower is not available, the inverter function
remains disabled and therefore no AC output power. When the inverter
mode is OFF, you cannot manually turn the inverter function ON or OFF
by using the Power button.

1. Press and hold the Power button for five seconds.

2. Press the Power button once.

The LED screen will flash “In” intermittently.

3. Press the Select button once.

The LED screen will display the present (or most recent) inverter
mode setting.
Example, “In1” for an inverter mode setting of ON or “In0” for an
inverter mode setting of OFF.

Table 3-1 Charging Current Guidelines

AC Input Circuit Breaker
or fuse size
(Amps)

Charger DC Current
Setting
(Amps)

Maximum By-pass AC
Current Available
(Amps)

15

5

12.5

15

9.5

35

4.0

55

0

20

5

17.5

15

14.5

35

9.0

55

5.0

30

5

27.5

15

24.5

35

19.0

55

15.0