4–6

975-0467-01-01

Status LED During Inverter Mode

The following summarizes the behavior of the Status LED during Inverter
mode.

Table 4-1 Status LED during Inverter Mode

Status LED

Display Screen

Condition

Solid
YELLOW

12.8

(where 12.8 is an
example of battery
voltage)

Select button is pressed to display Input Battery Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.

11

(where 11 is an
example of current)

Select button is pressed to display Input Current.
The Input Current LED lights up.
Value in display screen is shown as Amps.

0.85

(where 0.85 is an
example of output
power in Kilowatts)

Select button is pressed to display Output Power.
The Output Power LED lights up.
Value in display screen is shown as Kilowatts.

5A

or

15A

or

35A

or

55A

Select button is pressed to display present Charging Current
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.

IN0

or

In1

Select button is pressed to display present Inverter Mode
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.

aL0

or

AL1

Select button is pressed to display present Alarm setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.

sdL

or

sdH

Select button is pressed to display present Shutdown setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.

E05

through

e07

Warning condition detected while AC output power is still
available.
See

Table 5-1, “Error Codes Displayed on the Display Panel

Screen” on page 5–5

.

Advertising