Table a-1, Charger output current vs. ac input voltage – Xantrex Technology ENERGY HW 1000 User Manual

Page 71

Advertising
background image

Charger Output Current vs. AC Input Voltage

975-0467-01-01

A–7

Charger Output Current vs. AC Input Voltage

When the

Freedom HW

is charging batteries from a weak shore power

source the AC voltage may fall as the

Freedom HW

draws current. To

reduce the chance of the shore power voltage collapsing below the
configured transfer level the

Freedom HW

will reduce the charging

current at low shore power voltage according to the following graph:

Table A-1 Charging Voltage

Battery Type

Bulk/Absorption (Volts)

Float (Volts)

Flooded

14.4

13.5

GEL

14.2

13.8

AGM

14.3

13.4

Fixed

13.5

13.5

95V

105V

135V

55A

35A

Advertising