Xantrex Technology ENERGY HW 1000 User Manual

Page 36

Advertising
background image

3–6

975-0467-01-01

4. Continue pressing the Select button to cycle through the two settings

– “In1” and “In0” until you reach the desired setting.

5. Press and hold the Select button for five seconds to make the setting

permanent.

To adjust the alarm setting:

By default the
alarm is set to
ON.

ON (“AL1”) will sound the alarm on all warning and fault conditions.

OFF (“AL0”) will mute the alarm.

1. Press and hold the Power button for five seconds.

2. Press the Power button twice.

The LED screen will flash “AL” intermittently.

3. Press the Select button once.

The LED screen will display the present (or most recent) alarm
setting.
Example, “AL1” for an inverter mode setting of ON.

4. Continue pressing the Select button to cycle through the two settings

– “AL0” and “AL1” until you reach the desired setting.

5. Press and hold the Select button for five seconds to make the setting

permanent.

To adjust the under voltage shutdown setting:

By default the
low voltage
setting is set to
Low.

Low (“sdL”) sets the under voltage shutdown threshold to 10.5 V.

High (“SdH”) sets the under voltage shutdown threshold to 11.8 V.

1. Press and hold the Power button for five seconds.

2. Press the Power button three times.

The LED screen will flash “Sd” intermittently.

3. Press the Select button once.

The LED screen will display the present (or most recent) low voltage
setting.
Example, “SdL” for a low shutdown voltage setting.

4. Continue pressing the Select button to cycle through the two settings

– “SdH” and “SdL” until you reach the desired setting.

5. Press and hold the Select button for five seconds to make the setting

permanent.