Routine maintenance –14, Freedom hw, Batteries –14 – Xantrex Technology ENERGY HW 1000 User Manual

Page 52: Table 4-3, Battery charging voltage and current settings –14, Routine maintenance, Freedom hw unit, Batteries

Advertising
background image

4–14

975-0467-01-01

Table 4-3

below illustrates the battery charging voltage and current

settings.

Routine Maintenance

Freedom HW

Unit

Minimal maintenance is required to keep your

Freedom HW

operating

properly. Periodically you should:

Clean the exterior of the unit with a damp cloth to prevent the
accumulation of dust and dirt.

Ensure that the DC cables are secure and fasteners are tight.

Make sure the ventilation openings are not clogged.

Batteries

When possible, you should recharge your batteries whenever a low
voltage warning or a shutdown occurs with the

Freedom HW

. This gives

the batteries a much longer life than recharging when the batteries have
been almost completely discharged.

Table 4-3 Battery Charging Voltage and Current Settings

Battery Type

Bulk/Absorption
Voltage (Volts)

Float Voltage
(Volts)

Charge Current
(Amps)

Float Current
(Amps)

Flooded

14.4

13.5

5, 15
35, 55

1.5
4.5

GEL

14.2

13.8

5, 15
35, 55

1.5
4.5

AGM

14.3

13.4

5, 15
35, 55

1.5
4.5

Fixed

13.5

13.5

5, 15, 35, 55

not applicable