A–2

975-0467-01-01

Electrical Specifications: Inverter Mode

DC Input

Low operating voltage range
“SdL” setting

10.5–15.5 V

High operating voltage range
“SdH” setting

11.8–15.5 V

Under voltage alarm/shutdown
Under voltage recovery
“SdL” setting

10.5/11.0 V
12.0 V

Under voltage alarm/shutdown
Under voltage recovery
“SdH” setting

11.8/12.3 V
12.6 V

Safe non-operating voltage range

0–16 Vdc

Normal voltage

12.5V

Nominal current at full load

100A

AC Output

Output voltage

120 Vac

Continuous power

1.0kW @ 25 °C

Surge power

17A
(2kW for 200 ms)

Max short-circuit current

55A peak

Frequency

60 Hz

Wave shape

Modified Sinewave

Power derating above 40 °C ambient
temp

See

“Invert Power Derating vs.

Ambient Temperature” on
page A–6

.

Peak efficiency

≥88%

Full load efficiency

≥85%

Other

No load input power (producing
output voltage)

≤10W

Off mode current draw

≤3mA