Warning Messages

975-0467-01-01

5–5

Warning Messages

Warning messages in the form of audible alarms and error codes that
appear on the display panel screen to alert you to an impending system
change. Warnings do not affect operation.

With the exception of the error codes displayed on the screen, only the
audible alarm can be enabled or disabled. Follow the steps in

“To adjust

the alarm setting:” on page 3–6

to change the alarm settings.

The error codes are listed in

Table 5-1

below. The text in the Error Code

column appears on the display screen of the display panel.

Table 5-1 Error Codes Displayed on the Display Panel Screen

Error Code Condition

Mode

Action

E01

Low battery voltage
shutdown
< 10.5 Vdc (“SDL”)
< 11.8 Vdc (“SDH”)

Inverting

Check battery status and recharge if
necessary.

Check for proper DC cable sizing.

Check for loose connections and tighten if
necessary.

E02

High battery voltage
shutdown
(> 15.5 Vdc)

Inverting

Check for external charging sources, such
as an over voltage alternator, and
disconnect if necessary.

E03

AC output overload
shutdown

Inverting

Reduce the loads connected to the AC
outlet of the unit.

Check appliances that have high-surge
ratings and disconnect if necessary.

E04

Over-temperature
shutdown

Inverting

Reduce the loads connected to the AC
outlet of the unit.

Check that the ventilation grille is not
blocked.

Check for ambient temperature and move
the unit to a cooler location whenever
possible.

E05

Low battery voltage
detected
< 11.0 Vdc (“SDL”)
< 12.3 Vdc (“SDH”)

Inverting

Check battery status and recharge if
necessary.

Check for proper DC cable sizing.

Check for loose connections and tighten if
necessary.

E06

AC output overload
warning

Inverting

Reduce the loads connected to the AC
outlet of the unit.