VEGA VEGAPULS 51V…54V User Manual
Page 11
VEGAPULS 51 V … 54 V
11
VEGAPULS …
51 V
52 V
53 V
54 V
Signal output
digital meas. signal
•
•
•
•
Voltage supply
– two-wire technology (voltage
supply and signal output
via one two-wire line)
•
•
•
•
Process connection
– G1
1
/
2
A; 1
1
/
2
" NPT
•
•
–
–
– DN 50; ANSI 2"
–
–
•
•
– DN 80; ANSI 3"
–
–
•
•
– DN 100; ANSI 4"
–
–
•
•
– DN 150; ANSI 6"
–
–
–
•
Adjustment
– with PC
•
•
•
•
– with adjustment module in sensor
•
•
•
•
– with adjustment module in external
indicating instrument
•
•
•
•
– with signal conditioning instrument
•
•
•
•
Antenna material
– PP
•
–
–
–
– PPS/StSt
•
–
–
–
– PTFE/StSt
–
•
–
–
– PTFE
–
–
•
–
– StSt
–
–
–
•
Survey of features
• Application preferably of liquids in storage
tanks or vessels
• Meas. range 0 …20 m
• Ex-approved in IEC or ATEX
classification EEx ia [ia] IIC T 6
• Integral measured value indication
Types and versions - Survey
Survey