Standpipe measurement in inhomogeneous products – VEGA VEGAPULS 51V…54V User Manual

Page 32

Advertising
background image

32

VEGAPULS 51 V … 54 V

Standpipe measurement in
inhomogeneous products

If you want to measure inhomogeneous products
or laminated products in surge pipe it must
have long holes or slots. These openings ensure
that the liquid is mixed and balanced at the
correct level.

Openings in a surge pipe for mixing of
inhomogeneous products

The more inhomogeneous the measured
product, the closer the openings should be.

For reasons of radar signal polarization the
holes and slots must be positioned in two
rows displaced by 180°.

The mounting of the radar sensor is then
such that the type plate is in one axis with the
row of holes.

Row of holes in one axis with the type plate

Type plate

slightly inhomogeneous
liquids

inhomogeneous liquids

homogeneous
liquids

Mounting and installation - Measurement in standpipe