VEGAPULS 51 V … 54 V
Flange dimensions acc. to ANSI
D = outer flange diameter
b = flange strength
k = diameter of hole circle
d
1
= seal ledge diameter
f
= seal ledge strength
1
/
16
" = ca. 1,6 mm
d
2
= diameter of holes
External indicating instrument VEGADIS 50
Adjustment module MINICOM
Mounting on carrier rail 35 x 7,5 acc. to EN 50 022 or flat
screwed
Note:
Cable diameter of the connection cable min.
5 mm and max. 9 mm.
Otherwise the seal effect of the cable entry will
not be ensured.
Adjustment module for insertion in series 50
sensors or into the external indicating
instrument VEGADIS 50
Size
Flange
Seal ledge
Holes
D
b
k
d
1
No.
d
2
2" 150 psi
152,4
20,7
120,7
91,9
4
19,1
3" 150 psi
190,5
25,5
152,4
127,0
4
19,1
4" 150 psi
228,6
25,5
190,5
157,2
8
19,1
6" 150 psi
279,4
27,0
241,3
215,9
8
22,4
Technical data - Dimensions
;;;;;;;;;;;;;
;;;;;;;;;;;;;
;;;;;;;;;;;;;
;;
;;
;;
;;
;;
;;