VEGA VEGAPULS 51V…54V User Manual

Page 24

Advertising
background image

24

VEGAPULS 51 V … 54 V

Flange dimensions acc. to ANSI

D = outer flange diameter
b = flange strength
k = diameter of hole circle
d

1

= seal ledge diameter

f

= seal ledge strength

1

/

16

" = ca. 1,6 mm

d

2

= diameter of holes

External indicating instrument VEGADIS 50

Adjustment module MINICOM

Mounting on carrier rail 35 x 7,5 acc. to EN 50 022 or flat
screwed

Note:

Cable diameter of the connection cable min.
5 mm and max. 9 mm.
Otherwise the seal effect of the cable entry will
not be ensured.

Adjustment module for insertion in series 50
sensors or into the external indicating
instrument VEGADIS 50

Size

Flange

Seal ledge

Holes

D

b

k

d

1

No.

d

2

2" 150 psi

152,4

20,7

120,7

91,9

4

19,1

3" 150 psi

190,5

25,5

152,4

127,0

4

19,1

4" 150 psi

228,6

25,5

190,5

157,2

8

19,1

6" 150 psi

279,4

27,0

241,3

215,9

8

22,4

Technical data - Dimensions

;;;;;;;;;;;;;

;;;;;;;;;;;;;

;;;;;;;;;;;;;

;;

;;

;;

;;

;;

;;

Advertising