4 adjustment, 1 indicating and adjustment elements, 1 indicating and adjustment ele- ments – VEGA VEGAMET 514 User Manual

Page 13: Circuit board, Front plate vegamet 514

Advertising
background image

VEGAMET 514

13

Adjustment

4 Adjustment

4.1 Indicating and adjustment ele-

ments

Circuit board

A rotary switch is located on the circuit
board. It is used for adjustment of the instru-
ment address on DISBUS. This setting is
necessary if several VEGAMET signal condi-
tioning instruments are linked via the DISBUS
or if you control a VEGADIS 174 indicating
instrument via the DISBUS.

The adjustment range 1 … F corresponds to
the DISBUS addresses 1 … 15.
Factory setting: 1

Note:

With address 0 the VEGAMET does not par-
ticipate in the DISBUS communication.

Rotary switch

The set instrument address on the DISBUS
can be indicated via the LC display.

Note

If several VEGAMET are linked via the
DISBUS, each address must only be
assigned once!

8

7

6

5

4

0

F

E

D

C

B

A

9

3 3

2

1

10
11
12

13

14

15

Front plate VEGAMET 514

without adjustment

with adjustment

module

module

1 LCD (4 lines with 6 figures each, illuminated) for clear text

indication

2 LED chain (yellow) for quasi-analogue indication of the

measured value

3 Keys for menu adjustment
4 Connection socket for VEGACONNECT
5 LED (yellow) lights if the relay is energised (standard

setting)

6 LED (red), lights if fail safe relay is deenergised
7 LED (green), lights if operating voltage is on

Rotary switch