VEGA VEGAPULS 81 User Manual

Page 16

Advertising
background image

16

VEGAPULS 64 and 81

Types and versions: Configuration of measuring systems

Measuring system with 1 … 15 VEGAPULS 81 sensors (type C) per
two-wire line with separate power supply on the processing system
VEGALOG 571

• Digital output signal; signal processing in the processing system.

• 15 sensors on one two-wire line. The two-wire line transmits the digital output signal as well as

the superimposed adjustment signal of up to 15 sensors. The power supply is made sepa-

rately by a local voltage source.

• Approved in Ex Zone 0. Supply and output signal in EEx e (increased safety).

• Adjustment and parameter adjustment via a PC and the adjustment program VVO. The PC is

directly connected to the computer module of the processing system via an interface cable
(RS 232).

• An indicating instrument with digital and analogue indication is optionally integrated in the

sensor.

• Optionally an external digital/analogue indication. The indication can be separated from the

sensor in Ex zone 0 up to 25 m.

• The max. permissible resistor of the two-wire signal line is 15

per wire or max. 1000 m cable

length between sensor and processing system.

VEGALOG

571 CPU

VEGALOG

571 EV

2

2

2

2

2

CPU

4

4

+

+

2

+

2

2

2

2

Current outputs

Voltage outputs

Relay outputs

Transistor outputs

Fail safe outputs

Indication outputs

Digital connectability
Connection to all BUS-
systems

Outputs (see also Product
Information “Processing

system VEGALOG 571“)

VEGADIS 10

Processing system
VEGALOG 571 with input

cards in 19“-rack. Up to 15

sensors an one card and on
one two-wire line

VEGACONNECT

VEGAPULS 81

with digital signal

output, up to 15
sensors on one

two-wire line

PC with adjustment software
VEGA Visual Operating

Screened cable for strong electromag-
netic interferences

Ex-area

Non-Ex-area

EEx i

EEx e

EEx i

EEx e

EEx e

EEx i

EEx e

EEx e

Advertising