VEGA VEGAPULS 81 User Manual
Page 39
VEGAPULS 64 and 81
39
For reasons of the radar signal polarization the
holes and slots must be positioned in two rows
displaced by 180
°
.
The mounting of the radar sensor is then such
that the type plate of VEGAPULS 64 or the
casting nose of VEGAPULS 81 is in one axis
with the rows of holes.
Surge pipe with stop valve
When using a stop valve in the surge pipe, it is
possible to carry out maintenance and service
work without opening the vessel (e.g. with
liquid gas or toxic products).
Requirement for an interference free operation
is a ball valve outlet corresponding to the pipe
diameter. The ball valve must not have any
coarse edges or throats in the outlet against
the measuring pipe.
VEGAPULS 64: Row of holes in one axis with
the type plate
Lockable measuring pipe on a pipe antenna
system
VEGAPULS 81: Row of holes in one axis with
the casting nose
Type plate
Casting nose
DN 50
ø50
Ball valve
Breather hole
Mounting and installation: Measurements of liquids