Heavy product movements, Build-up, Inflowing product – VEGA VEGAPULS 81 User Manual

Page 45

Advertising
background image

VEGAPULS 64 and 81

45

Mounting and installation: False echoes

Heavy product movements

Heavy turbulences in the vessel, e.g. by

strong stirrers or strong chemical reactions
aggravate the measurement. A bypass pipe of

sufficient size, provided that there is not build-

up in the measuring pipe, always ensures a

reliable measurement even with heavy

turbulences in the vessel.

Products which cause slight build-up can be
measured by using a bypass pipe with 100

mm nominal width or more. In a bypass pipe of

this size, slight build-up does not cause prob-

lems.

Build-up

If the radar sensor is mounted too close to the

vessel wall, build-up on the vessel walls will

cause false echoes. Position the radar sensor

at a sufficient distance to the vessel wall.

Heavy product movements

Inflowing product

Do not mount the instrument above or in the
filling stream. Ensure that they detect the

product surface and not the inflowing material.

Build-up

Inflowing solid

Inflowing liquid

Correct

Wrong

Correct

Wrong

Correct

Wrong

Correct

Wrong

50 %

0 %

Advertising