VEGAPULS 64 and 81

Set-up: Adjustment with signal conditioning instrument

Single measurement

OK

Reset MST1

OK

Delete MST1

OK

Reset?

OK

Reset now?

OK

Reset MST1

The input component for measurement loop 1

is hence reset. The menu reset MST1 appears

again.

Reset MST2

OK

Delete MST2

OK

Reset OK?

OK

Reset now OK?

OK

Reset MST2

The input component for measurement loop 2

is hence reset. The menu reset MST2 appears

again.

You have hence adjusted the default values

and deleted old adjustments.

ESC

Single measurement

ESC

Reset configuration

Reset sensor values

“Reset sensor values“ is not necessary and

cannot be enquired as you have also deleted
the sensor values with the measurement loop

reset.

Reset linearization curves

Here you can reset 1 … 3 linearization curves.

If you do not want to use new linearization

curves, you can be skipped and the reset

menu can be quit.

Quit reset menu

ESC

Reset VEGAMET

ESC

Additional functions

You are now again in the main menu stage

which is below the stage of the measured

value indication.

In the menu “

Configuration“ you now create

new measurement loops. The parameter ad-

justment menus cannot yet be enquired.

Configure measurement loop

Configuration

OK

Configuration inputs

Configuration measurement loop

OK

MST1 not configured

OK

Application not configured

+…–

Level

OK

Data will be saved

Sensor/Input, no sensor

+…–

Sensor/Input radar

OK

Sensor/Input radar

Kind not configured

+…–

Standard

OK

Standard

Option not determined

+…–

Option none

OK

Measurement loop is created

After some seconds the display indicates

“Option none“.

Sensor co-ordination

OK

+

A input 1

OK

A input 1

The statement of the position is important for

flow or differential measurements (linked appli-

cation. There are two sensor positions (A and

B). Each input must be co-ordinated to a posi-
tion. For pure level and distance measure-

ments the radar sensors are always co-

ordinated to input A.

Note:

If you work with a VEGAMET 515 V and you

have connected a second sensor, measure-

ment loop 2 must also be configured. Hence

push twice the key “ESC“ and MST1 level
appears.

MST2 not configured

Configure here measurement loop 2 (MST2)
like you proceeded for measurement loop 1

(configure measurement loop).

ESC

Sensor co-ordination

ESC

Measurement loop 1 level (or dis-

tance) or measurement loop 2 level