8 OPTIONS

8.1 CONNECTIVITY OPTIONS

3-ph SNMP/WEB plug-in adapter
SNMP - Simple Network Management Protocol

The 3-ph SNMP/WEB plug-in adapter is an interface to the Ethernet
Network
, and provides UPS information via the standard SNMP
Protocol
(UPS-MIB (RFC-1628); GE Single MIB; GE Parallel MIB).
The UPS can therefore be managed by a Network Management
System (NMS)
or by our applications (for instance GE iUPSGuard or
GE Data Protection)
, which uses this information to determine the
state of the UPS in order to guarantee safe and orderly shut-
down of the server, when needed.

GE iUPSGuard
GE’s iUPSGuard is a remote monitoring solution for UPS, providing
status monitoring and alarm notification that supports all GE UPS
product lines, anytime, anywhere.
iUPSGuard provides current and detailed information about UPS
operation, including its configuration, internal alarms and
operating conditions over web.
iUPSGuard notifies personnel of critical alarms and events via
email or SMS, allowing a user or GE technician to make timely
decisions on critical conditions.
In addition, comprehensive data collection and analysis improves
diagnostics capability and enhances response time.
Continuous monitoring and ongoing maintenance help ensure
maximum performance of your UPS equipment as it protects
business critical applications.

GE Data Protection
GE Data Protection
software can communicate with the UPS over
RS-232, USB or SNMP to receive status information and
measurement values of the UPS. In case of a critical condition
(time on battery, remaining battery autonomy time or low battery)
for the Load, the software starts a controlled shut-down.
An enhanced alarm management system provides the possibility
to start applications, send messages, and send e-mails for every
upcoming or disappearing alarm.


8.2 OPTIONS IN UPS CABINET

eBoost™ Operation Mode
High efficiency operating mode, where the load is supplied directly by utility
and automatically transferred to inverter if the voltage is out of prescribed
tolerances.

RPA Kit
Redundant Parallel Architecture

Up to 6 units parallel possible for redundancy or capacity in RPA
configuration.