Code description function, Spectra, Rms circuit breakers with microentelliguard – GE Industrial Solutions Spectra RMS Molded Case User Manual

Page 2: Trip unit the micro entelliguard

Advertising
background image

GEH-702 Users Manual



Spectra

®

RMS Circuit Breakers with microEntelliGuard

TM

Trip Unit

The microEntelliGuard

TM

Trip Unit is the latest and most advanced trip unit available in the Spectra line of

molded case circuit breakers. The trip unit design is based on the EntelliGuard trip unit platform. The
microEntelliGuard

TM

Trip Unit incorporates many of the advanced features and protective functions available

on the EntelliGuard

Trip Unit and is available in the 600-amp Spectra G and 1200-amp Spectra K frames.

Spectra breakers with microEntelliGuard

TM

Trip Units allow you to select the enhanced system protection,

coordination, and communication options required for the application.

Standard Protection

Advanced Protection

Advanced Features

Long Time

Neutral Protection

Metering (Basic/Advanced)

Short Time

Zone Selective Interlock (ST/GF/INST)

Communications (Modbus)

Instantaneous

Reduced Energy Let-through

Waveform Capture

Ground Fault (trip or alarm)

Table 1. Catalog Number Nomenclature

SK PC 36 12 L4 R 6

Code Description

Function

SK

SK1200

Frame Designation

HC
LC/TC

1

PC/SC

1

HH
LL/TT

1

PP/SS

1

35kA at 480Vac
65kA at 480Vac

Standard UL Rating

100kA at 480 Vac
35kA at 480Vac
65kA at 480Vac

100% Continuous UL Rating

100kA at 480 Vac

Interruption Rating

3, 4 or 6 3 Poles, 480Vac or 600Vac

Poles, Max UL Voltage

08

800 Amps

10

1000 Amps

SK Frame

12

1200 Amps

L3

LSI

L = Long Time

S = Short Time

L4

LSIG

I = Instantaneous

L5

LSIA

G = Ground Fault

A = Ground Fault Alarm

L7

LSI-CP

CP = Control Power

X

None

K

Neutral Protection

Z

ZSI (ST/GF)

T

ZSI (ST/GF/INST)

R

RELT

L

ZSI (ST/GF) + RELT

M

ZSI (ST/GF) + Neutral Protection

N

ZSI (ST/GF) + RELT + Neutral Protection

V

RELT + Neutral Protection

P

ZSI (ST/GF/INST) + RELT

S

ZSI (ST/GF/INST) + Neutral Protection

W

ZSI (ST/GF/INST) + RELT + Neutral Protection

X

Metering (Basic)

2

Metering (Basic) + Modbus

6

Metering (Adv) + Modbus + Waveform Capture

8

Metering (Adv) + Modbus + Waveform Capture + Protective Relays




1. SKT and SKS catalog codes are optimized for selectivity and will carry a

480Vac maximum voltage rating.

Max Amps


Standard Protection
Functions







Advanced Protection
Functions





Advanced Features &
Communication

Advertising