3-02 Min. Reference

Range:

Function:

[-4999 - 4999]

Sets limits for set-point and feedback.

3-03 Max. Reference

Range:

Function:

[-4999 - 4999]

Sets limits for set-point and feedback.

3-10 Preset Reference

Range:

Function:

[-100.00 - 100.00]

Preset [0] works as set-point.

4-12 Motor Speed Low Limit

Range:

Function:

[0.0 - 400 Hz]

Lowest possible output frequency.

4-14 Motor Speed High Limit

Range:

Function:

[0.0 - 400.00 Hz]

Highest possible output frequency.

6-22 Terminal 60 Low Current

Range:

Function:

[0.00 - 19.99 mA]

Normally set to 0 or 4 mA.

6-23 Terminal 60 High Current

Range:

Function:

[0.01 - 20.00 mA]

Normally (default) set to 20 mA.

6-24 Terminal 60 Low Feedback Value

Range:

Function:

[-4999 - 4999]

Value corresponding to P. 6-22 setting.

6-25 Terminal 60 High Feedback Value

Range:

Function:

[-4999 - 4999]

Value corresponding to P. 6-23 setting.

6-26 Terminal 60 Filter Time Constant

Range:

Function:

[0.01 - 10.00 s]

Filter for suppressing electrical noise.

7-20 Process CL Feedback Resource

Range:

Function:

[]

Choose [2] analog input 60.

7-30 Process PI Normal/Inverse

Range:

Function:

[]

Most PI controllers are “Normal”.

7-31 Process PI Anti Windup

Range:

Function:

[]

Leave Enabled normally.

7-32 Process PI Start Speed

Range:

Function:

[0.0 - 200.0 Hz]

Choose expected normal running speed.