5.6 GE Drive Control Profile

5.6.1 Control Word According to GE Drive Control Profile

Bit

Bit value = 0

Bit value = 1

00

Preset reference select - lsb

Preset reference select - lsb

01

Preset reference select - msb

Preset reference select - msb

02

DC brake

Ramp

03

Coasting

No coasting

04

Quick stop

Ramp

05

Freeze output

No freeze output

06

Ramp stop

Start

07

No function

Reset

08

No function

Jog

09

Ramp 1

Ramp 2

10

Data invalid

Data valid

11

No function

Relay 01 active

12

No function

No function

13

Setup 1

Setup 2

14

No function

No function

15

No function

Reverse

5.6.2 Explanation of the Control Bits

Bits 00/01
Bits 00 and 01 are used to choose between the four reference values, which are pre-programmed in par. 3-10 Preset Reference according to the following table:

Programmed ref. value

Parameter

Bit 01

Bit 02

1

3-10 [0]

0

0

2

3-10 [1]

0

1

3

3-10 [2]

1

0

4

3-10 [3]

1

1

NB!
In par. 8-56 Preset reference a selection is made to define how Bit 00/01 gates with the corresponding function on the digital inputs.

Bit 02, DC brake:
Bit 02 = “0” leads to DC braking and stop. Braking current and duration are set in par. 2-01 DC Brake current and 2-02 Braking time.
Bit 02 = “1” leads to ramping.

Bit 03, Coasting:
Bit 03 = “0” shuts off the output transistors causing the motor to coast to a standstill.
Bit 03 = “1” enables the frequency converter to start the motor if the other starting conditions have been fulfilled.