Af-60 lp™ micro drive operating instructions – GE Industrial Solutions AF-60 LP Micro Drive Operating Instructions User Manual

Page 61

Advertising
background image

8.1.2 Mains Supply 3 x 200 - 240 VAC

Normal overload 150% for 1 minute
Frequency converter
Typical Shaft Output [kW]

0.25

0.37

0.75

1.5

2.2

3.7

Typical Shaft Output [HP]

0.33

0.5

1

2

3

5

IP 20

Unit Size

M1

Unit Size

M1

Unit Size

M1

Unit Size

M2

Unit Size

M3

Unit Size

M3

Output current

Continuous (3 x 200-240 V ) [A]

1.5

2.2

4.2

6.8

9.6

15.2

Intermittent (3 x 200-240 V ) [A]

2.3

3.3

6.3

10.2

14.4

22.8

Max. cable size:

(mains, motor) [mm

2

/AWG]

4/10

Max. input current

Continuous (3 x 200-240 V ) [A]

2.4

3.5

6.7

10.9

15.4

24.3

Intermittent (3 x 200-240 V ) [A]

3.2

4.6

8.3

14.4

23.4

35.3

Max.mains fuses [A]

See Section Fuses

Environment

Estimated power loss [W], Best case/
Typical

1)

14.0/

20.0

19.0/

24.0

31.5/

39.5

51.0/

57.0

72.0/

77.1

115.0/

122.8

Weight enclosure IP20 [kg]

1.1

1.1

1.1

1.6

3.0

3.0

Efficiency [%], Best case/Typical

1)

96.4/

94.9

96.7/

95.8

97.1/

96.3

97.4/

97.2

97.2/

97.4

97.3/

97.4

Table 8.2: Mains supply 3 x 200 - 240 VAC

1.

At rated load conditions.

8.1.3 Mains Supply 3 x 380 - 480 VAC

Normal overload 150% for 1 minute
Frequency converter
Typical Shaft Output [kW]

0.37

0.75

1.5

2.2

3.0

4.0

Typical Shaft Output [HP]

0.5

1

2

3

4

5

IP 20

Unit Size

M1

Unit Size

M1

Unit Size

M2

Unit Size

M2

Unit Size

M3

Unit Size

M3

Output current

Continuous (3 x 380-440 V) [A]

1.2

2.2

3.7

5.3

7.2

9.0

Intermittent (3 x 380-440 V) [A]

1.8

3.3

5.6

8.0

10.8

13.7

Continuous (3 x 440-480 V) [A]

1.1

2.1

3.4

4.8

6.3

8.2

Intermittent (3 x 440-480 V) [A]

1.7

3.2

5.1

7.2

9.5

12.3

Max. cable size:
(mains, motor) [mm

2

/ AWG]

4/10

Max. input current

Continuous (3 x 380-440 V ) [A]

1.9

3.5

5.9

8.5

11.5

14.4

Intermittent (3 x 380-440 V ) [A]

2.6

4.7

8.7

12.6

16.8

20.2

Continuous (3 x 440-480 V ) [A]

1.7

3.0

5.1

7.3

9.9

12.4

Intermittent (3 x 440-480 V ) [A]

2.3

4.0

7.5

10.8

14.4

17.5

Max. mains fuses [A]

See Section Fuses

Environment
Estimated power loss [W], Best case/
Typical

1)

18.5/

25.5

28.5/

43.5

41.5/

56.5

57.5/

81.5

75.0/

101.6

98.5/

133.5

Weight enclosure IP20 [kg]

1.1

1.1

1.6

1.6

3.0

3.0

Efficiency [%], Best case/
Typical

1)

96.8/

95.5

97.4/

96.0

98.0/

97.2

97.9/

97.1

98.0/

97.2

98.0/

97.3

Table 8.3: Mains supply 3 x 380 - 480 VAC

1.

At rated load conditions.

AF-60 LP™ Micro Drive Operating Instructions

60

DET-579A

8

Advertising