Electromagnetic Flow Meter

FW: 842018/842009

3. Flow Sensor

The following conditions must be satisfied to get the full benefit of the
MagFlux

®

flow sensor.

Minimum conductivity

• The conductivity of the media must be greater than 5 µS/cm.

Liner selection

• Use Teflon

®

lining for chemicals and food industries

• Use hard rubber lining for drinking water and waste water
• Use soft rubber lining for water with abrasive particles

Electrode selection

• Steel AISI 316TI-1.4571 for general purpose, sewage, water and district

heating systems

• Hastelloy for sea water
• Titanium and platinum for chlorine and other aggressive chemicals

Mounting location

• To obtain a stable and accurate flow measurement, it is very important

that the flow sensor is mounted correctly in the pipe system

• There must be no flow fluctuations
• Avoid locations where vacuum can occur; especially for flow sensors

with Teflon™ linings

• Avoid locations with vibrations from for example pumps
• Avoid locations with extensive temperature changes
• Avoid corrosive environments and locations with a great risk of con-

densation, or consult factory for special builds for these locations

• Take care that condensate and water cannot enter the connector box

on the flow sensor.

• There must be sufficient free space around the flow sensor.
• IMPORTANT: Observe that the correct flow direction is set in the

MagFlux

®

"Converter Setup" menu and in the "Service Menu". Default

flow direction is "A" (flow direction towards left).

Advertising