4. Flow Converter

Electrical Mounting

Warning: The MagFlux

®

flow converter / flow sensor must not be

mounted in explosion hazardous areas!

Loosen the four screws (position indicated by arrows) and remove the
display unit to gain access to the terminals.

521255

Ground from

flo

w pipe

Red

White

White

Blac

k

Green

White

L2

E2

E1

L1

GND

Mains

supply

-mA-

-RE2-

-RE1-

-DI1-

-Display-

+

+

A

B

DI COM

C

NO

NO

PE

N

L

-

-

FUSE

www.mjk.com

Fuse rating:

100 mA

T @ 115

V

A

C

63 mA

T @ 230

V

A

C

521254

Connection f

or top

mounted operator panel

Liv

e

Neutral

Protectiv

e ear

th

PE

N

L

Te

rminals

for remote

operator panel

+

A

B

-

Up to four MagFlux

®

flow sensors can

be connected to one operator panel:

4 wire cable.

2 wire cable.

A, B

+, A, B, -

4-20 mA (Activ

e.

)

Max.

500

Electronic rela

y

M

ax

. 5

0

V

1

20

m

A

re

si

st

iv

e

lo

ad

Mechanical rela

y

Max.

50

V 1A resistiv

e load

< 5

VDC =

O

; > 10

VDC =

I

Max.

30

VDC

+

DI COM

COM

NO

NO

-

DO1

DI

DO2

AO

FUSE

MAINS SUPPLY

Sensor #1

Sensor #4

Operator

panel