Power Supply

The flow converter must be supplied from a properly fused mains outlet, a
24 volt AC outlet, or a 10 - 30 V DC power supply/battery.

Power Supply 230 V AC, 115 V AC or 24 V AC

Terminal

Designation

PE

Protective ground

N

230 / 115 / 24 V AC neutral

L

230 / 115 / 24 V AC live

Power Supply 10 - 30 V DC

Terminal

Designation

PE

Protective ground

DC neutral

+

DC live

The internal fuse ratings are:

Internal Fuse Ratings

Voltage

Rating

Order no.

Dimension

230 V AC

0.063 mA T

550030

5 x 20 mm

115 V AC

0.125 mA T

550035

5 x 20 mm

24 V AC

0.5 mAT

550049

5 x 20 mm

10 - 30 V DC

1.0 AT

550051

5 x 20 mm

The technical specifications/requirements for a 10 - 30 V DC power
supply/battery are:

Technical Specifications for 10 - 30 V DC Power Supply

Power consumption without display

< 5 W

Power consumption with display

< 8 W

Peak start current @12 V DC,1 second

Approx. 1,5 A

Peak start current @24 V DC,1 second

Approx. 1 A