Menu system for magflux converter converter setup – Xylem Magflux Electromagnetic Flow Meter User Manual

Page 90

Advertising
background image

90

EN 3.05 MagFlux Manual 1212

Electromagnetic Flow Meter

Calibrate Flow Now
First "View Flow Now" is displayed, and then afterwards you can cali-

brate the flow.

Type Password

0000

Back

Select

>

Service Menu

Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back On Stock
Back

Select

OK

OK

Sensor Calibration Code

Converter SW Ver.

Product Data

Sensor Calibration Code
7V3RI0

Back

Select

>

Back

Product ID

56136

Back

Select

>

Product type No.

0000207910

Back

Select

>

Track No.

00000

Back

Select

>

HW type No.

00000510250

Back

Select

>

OK

OK

OK

Reset Counter Time

Reset Counter 11
Systen Runtime 1632838
Since reset 426838
Runtime (days) 18
Back

Select

OK

Internal Meas. & Cal.

View Vgate
Coil Current
View ADC Factor
Calibrate Vground
Calibrate Vref
View Vwater
View Raw ADC
View ADC Current
Back

Select

>

Minimum Velocity

Minimum Velocity
0.100 m/
sec

Back

Select

>

View Vgate

Coil Current

View Vgate

3624

Back

Select

>

Coil Current

148

Back

Select

>

View ADC Factor

4.89011

Back

Select

>

Calibrate ADC ground

2270

Back

Select

>

View ADC Factor

Calibrate ADC Ground

Only f

or ter

minal use

Must not be surrended

A

B

C

D

E

Date

Modification

Scale:

MJK AUTOMATION A/S
Byageren 7
DK-2800 Nñrum
Fax: +45 45 56 06 46
Tel.: +45 45 56 06 56

Date:

Constructor:

Part no.:

Software version

Skala for tegning

Menu system for MagFlux Converter
Converter Setup

Service Menu

2006 - 09 - 20

841010

LSP

View ADC Current

View Raw ADC

View ADC Current
09593127.00000

Back

Select

>

Input noise 0.18%
Raw ADC 10791
Gain 4.000
Velocity 5.21656 m/sec
Flow 0.0055786500 m

3

/sec

Back

Select

>

View Vwater

0

Back

Select

>

View/Calibrate Vref

1208

Back

Select

>

View Vwater

View/Calibrate Vref

DN

00025

Back

Select

>

OK

Calibrate Flow now

View flow now
0.0019816387 m

3

/sec

Back

Select

>

Set Flow Direction
Follow Arrow A
Follow Arrow B

<A ----------------------------- B>

Back

Select

OK

OK

Converter 842009-005
Build 7659

Build 719

Bootload 840020-002

Sensor Direction Test

Calibration volume
The volume counter can be reset and a new value can be entered.

Only f

or ter

minal use

Must not be surrended

A

B

C

D

E

Date

Modification

Scale:

MJK AUTOMATION A/S
Byageren 7
DK-2800 Nñrum
Fax: +45 45 56 06 46
Tel.: +45 45 56 06 56

Date:

Constructor:

Part no.:

Software version

Skala for tegning

Menu system for MagFlux Converter
Converter Setup

Service Menu

2006 - 11 - 22

841010

LSP

Calibration Volume

Reset counter
Yes
No

Back

Select

OK

Reset counter
Yes
No

Back

Select

OK

OK

View counter
1163.1950000000 m

3

Back

Select

OK

OK

Set volume
1163.1950000000 m

3

Back

Select

OK

OK

Calibrate mA

Current
Set fixed current
Calib. current
DAC zero current
DAC top current
Back

Select

OK

Test Velocity

Set velocity

00.000 m/sec

Back

Select

>

Velocity

4.039745 m/sec

Flow

7.136209 m

3

/h

Back

Select

OK

OK

Enable test
Yes
No

Back

Select

OK

OK

Freeze Coil

Freeze coil
Positive
Negative

Back

Select

OK

Freeze coil
Disable
Enable

Back

Select

OK

OK

Read Event Log

No Hour Event Extension
1 1956 0 0
2 1956 3 0
3 1956 205 0
Back

Next

OK

No Hour Event Extension
18 306 205 0
19 306 208 0
20 163 206 0
Back

OK

Back On Stock

Recover Factory Settings
Cancel
Back On Stock

Back

Select

OK

OK

Current

20000 uA

Back Select >

OK

Set fixed current
Release mA
Minimum mA
4mA =
12 mA
20 mA
Maximum mA

Back Select OK

OK

Calib. current
20500 uA

Back Select >

OK

DAC zero current
3955 uA
776

Back Select >

OK

DAC top current
19997 uA
3814

Back Select >

Read sensor data

DN
00050

OK

Back

OK

Serial no
00006

OK

Back

OK

Sensor Cal
19600

OK

Back

OK

Sensor zero
0.000000 m

/h

OK

Back

3

Advertising