Ethernet port, Sis control, Mgp pro-initiated messages – Extron Electronics MGP Pro Series User Guide User Manual

Page 49

Advertising
background image

MGP Pro Series • Remote Configuration and Control

43

Ethernet Port

The rear panel Ethernet connector on the MGP Pro can be connected to an Ethernet LAN
or WAN. Communication between the MGP Pro and the controlling device can be via
Extron DataViewer or Telnet (a TCP socket using port 23). The Telnet port can be changed,
if necessary, via SIS (for information on connecting via Telnet, see

Connecting as a Telnet

Client

on page 108).

The Ethernet connection makes SIS control of the MGP Pro possible using a computer
connected to the same LAN or WAN. The SIS commands and behavior of the product are
identical to the commands and behavior the product exhibits when you are communicating
with it via a serial port.

Ethernet Cable

The Ethernet cable must be properly terminated for your application as either a straight-
through cable or a crossover cable (for pin assignments for these cables, see

D

LAN

connector

on page 8).

Default IP Addresses

To access the MGP Pro via the Ethernet port, obtain the IP address of the unit (and the
subnet mask and gateway address if needed) from your network administrator. If the IP
address has been changed to an address comprised of words and characters, you can
determine the actual numeric IP address using the ping (ICMP) utility (see

IP Address

on

page 105 for more details). If the addresses have not been changed, the factory-specified
defaults are:

IP address: 192.168.254.254

Subnet mask: 255.255.0.0

Gateway address: 0.0.0.0

SIS Control

The MGP Pro accepts SIS (Simple Instruction Set) commands through the RS-232/422
port on the rear panel, the RS-232 front panel Config port, and the LAN port. SIS
commands consist of one or more characters per command field. They do not require any
special characters to begin or end the command character sequence. Each response to
a command ends with a carriage return and a line feed (]), which signals the end of the

response character string. A string is one or more characters.

MGP Pro-initiated Messages

When a local event such as a front panel selection or adjustment takes place, the MGP
Pro responds by sending a message to the host. No response is required from the host.
Examples of MGP Pro-initiated messages are listed below (underlined).

(c)

Copyright

20nn

,

Extron

Electronics

, MGP

model

number

PRO

[

model

type

]

,

Vn

.

nn

,

60-nnnn-nn

Www,

DD

Mmm

YYYY

HH

:

MM

:

SS

The MGP Pro sends the copyright message when it is first powered on.

Model

number

is

462

or

464

, and

model

type

, if applicable, is

DI

or

3G-SDI

.

Vn.n

is the firmware

version number, and

60-nnnn-nn

is the unit part number.

The current date and time are displayed following the copyright message at power up if
the connection is via the Internet. (

Www

are the first three letters of the day of the week,

for example,

Mon

or

Fri

.)

Advertising