45

The command and response tables list valid ASCII (for Telnet) command codes, the
corresponding URL encoded (for web browsers) command codes, the responses of the
processor to the host, and a description of the command function or results from executing
the command.

Entering SIS Commands

Upper- and lowercase letters may be used interchangeably in the command field unless
otherwise specified.

Commands may be sent back-to-back without spaces, for example, 2*2!2*0B.

Numbers can be entered as 1 digit, or as 2 or 3 digits with leading zeros, for example,

8V

=

08V

=

008V

.

There are a few differences in how to enter the commands depending on whether you
are using Telnet or a web browser.

For control via a web browser, all non-alphanumeric characters must be
represented as the hexadecimal equivalent,

%xx

, where

xx

represents the

two-character hex byte. For example, a comma (,) would be represented as

%2C

.

When using these commands through a web browser, the URL reference
is used to shorten the examples. “URL” refers to the full URL of the control
interface and web page reference, including all path information, for example,

http://192.168.100.10/myform.htm

.

Some characters differ depending on what method you use to send the
commands:
Telnet

Web Browser

Escape key (hex

1B

)

W

[must not be encoded]

Carriage return (hex

0D

)

Pipe character (|) [must not be encoded]

NOTE: With Telnet you can use either the Escape E commands or the

W

commands, and the carriage return or the pipe character. With the web
browser, you are required to use the

W

commands and the pipe character.

In either method, the data string (shown in braces as {data} in the command
and response table is directed to the specified port, and must be encoded if it is
non-alphanumeric.

Symbol Definitions

]

=

CR/LF Carriage return with line feed (hex

0D

0A

)

}

=

Carriage return (no line feed) (hex

0D

)

For web browser commands, use the pipe character (|) instead of the soft return (}).

=

Space character

|

=

Pipe (vertical bar) character

E

=

<Escape> key (hex

1B

)

W

=

<Escape> key alternative

24,

27,

28

=

Superscript numbers correspond to error numbers, indicating the error

message displayed if the command is entered incorrectly or with invalid

parameters

(see

Error Responses

on page 44).