59

Command

ASCII (Telnet)
(Host to Processor)

Response
(Processor to Host)

Additional Description

Total Pixels
Set a specific value

11 *

X!

*

X1*

#

Tpx

X!

*

X1*

]

Set the total pixels value for
input

X!

to

X1*

.

X1*

= Auto-sensed value ± 512

lines or pixels.

Increment total pixels value

11 *

X!

+ #

Tpx

X!

*

X1*

]

Select the next higher total
pixels value for input

X!

.

Decrement total pixels value

11 *

X!

– #

Tpx

X!

*

X1*

]

Select the next lower total
pixels value for input

X!

.

View total pixels setting

11 *

X!

#

X1*

]

View the current total pixels
setting for input

X!

.

Active Pixels
Set a specific value

12 *

X!

*

X1*

#

Apx

X!

*

X1*

]

Set the active pixels value for
input

X!

to

X1*

.

Increment active pixels value

12 *

X!

+ #

Apx

X!

*

X1*

]

Select the next higher active
pixels value for input

X!

.

Decrement active pixels value

12 *

X!

– #

Apx

X!

*

X1*

]

Select the next lower active
pixels value for input

X!

.

View active pixels setting

12 *

X!

#

X1*

]

View current active pixels value
for input

X!

.

Active Lines
Set a specific value

13 *

X!

*

X1*

#

Aln

X!

*

X1*

]

Set the active lines value for the
input

X!

to

X1*

.

X!

= 1-19.

X1*

= Auto-sensed value ± 512

lines or pixels.

Increment active lines value

13 *

X!

+ #

Aln

X!

*

X1*

]

Select the next higher active
lines value.

Decrement active lines value

13 *

X!

– #

Aln

X!

*

X1*

]

Select the next lower active
lines value

View active lines setting

13 *

X!

#

X1*

]

View the current active lines
setting for input

X!

.

Advertising