Command and response table for, Mgp pro sis commands, Command and response table for mgp pro sis – Extron Electronics MGP Pro Series User Guide User Manual

Page 57: Commands, Beginning, Nput edid command, Only)

Advertising
background image

MGP Pro Series • Remote Configuration and Control

51

Command and Response Table for MGP Pro SIS Commands

Command

ASCII (Telnet)
(Host to Processor)

Response
(Processor to Host)

Additional Description

Input Selection
Select an input

X!

*

X@

!

Out

X@

•In

X!

]

Select input source

X!

for

window

X@

.

View input

X@

!

X!

]

View the input channel for the
selected window.

X!

= 1-19.

X@

= 0-4. 0 = all windows.

Input Video Type
Set video type

X!

*

X#

\

X!

Typ

X#

]

Set input

X!

to format

X#

.

For

X#

:

1 = RGB
2 = YUV-HD
3 = RGBcvS
4 = YUVi
5 = S-video
6 = Composite video
7 = HDMI or 3G/HD-SDI.

View video type

X!

\

X#

]

View video signal type

X#

for

input

X!

.

NOTE: It is recommended that virtual inputs be configured using the Windows-based control software (see the software

help file for the procedures).

EDID Resolution and Refresh Rate
Set input EDID resolution and
rate

E

A

X(

*

X1^

EDID

}

Edid A

X(

*

X1^

]

Set EDID resolution to scaler
resolution

X(

and the refresh

rate to

X1^

.

NOTE: All input EDID resolutions have available refresh

rates of 50 Hz and 60 Hz only except:

576p has 50 Hz only.

480p, Sharp 1080p, and 1080p CVT have 60 Hz
only.

For

X(

:

0 = Match output

14 = 1600x1200

1 = 640x480

15 = 480p

2 = 800x600

16 = 576p

3 = 852x480

17 = 720p

4 = 1024x768

18 = 1080i

5 = 1024x852

19 = 1080p

6 = 1024x1024

21 = 1280x800

7 = 1280x768

22 = 1360x768

8 = 1280x1024

23 = 1440x900

9 = 1360x765

24 = 1680x1050

10 = 1365x768

25 = 1080p Sharp

11 = 1366x768

26 = 1920x1200

12 = 1365x1024

27 = 1080p CVT

13 = 1400x1050

28 = 2048x1080

99 = Custom.

For

X1^

:

1 = 50 Hz
2 = 60 Hz.

NOTES:

The default is to match the output resolution:

X(

= 0,

X1^

= 0.

EDID resolutions are available only at 50 Hz and 60 Hz. If another rate is selected, the MGP Pro issues an E13 code.

View EDID resolution and rate

E

A EDID

}

X(

*

X1^

]

View current EDID resolution

X(

and rate

X1^

.

Save EDID

E

S 0EDID

}

Edid S 0

]

Save the EDID from the
connected output to Custom
EDID location 99.

Advertising